Comparison¶
The choices¶
- Subsoil category (A–E) and topographic category (T1–T4) of the building site: they give SS, CC and ST of the NTC spectrum.
- Tmin and Tmax: the smallest and the largest of the main vibration periods of the building, from the structural analysis. The comparison interval is [Tmin, 2·Tmax]: the factor 2 accounts for the lengthening of the period during the earthquake.
- Accelerations on screen: g or m/s². It changes only the display.
The following are set by the Ordinance and shown as such: TR = 475 years, η = 1 (5 % damping), horizontal spectrum.
The chart¶
Simplified NTC spectrum (green), regularised MS3 spectrum (red), MS3 spectrum of the study (dotted), [Tmin, 2·Tmax] band and verticals TB, TC, TD of the regularised spectrum. The circle marks the period of the maximum ratio. The T axis can be logarithmic.

The two conditions¶
| Condition | What is measured | Threshold |
|---|---|---|
| 1 · pointwise (maximum ratio) | the maximum of the ratio Se,MS3/Se,NTC over the interval | > 1.30 |
| 2 · integral (area ratio) | (AMS3 − ANTC)/ANTC, with A the area under the spectrum over the interval | > 20 % |
A value exactly equal to the threshold does not exceed it.
The outcome¶
- Simplified approach can be used: neither of the two conditions is met.
- Further investigations required: at least one is met. Geological, geophysical and geotechnical investigations are carried out; if they do not justify the simplified approach, a 1D or 2D local seismic response analysis is performed.
- Comparison not applicable: 2·Tmax exceeds 1.1 s (note 1 of the Ordinance). The conditions remain visible for information.
Below the conditions you find, for information, the share of points at a 0.01 s step where the MS3 spectrum exceeds the code spectrum: it is the reading made by the desktop program, not condition 1 of the Ordinance. The coloured dot on the Comparison tab sums up the outcome from any tab.
Found an error on this page? Let us know or open a Pull Request.