Skip to content

FAQ

Why is the outcome different from the one of the desktop program? The desktop read condition 1 as a percentage of points above the code spectrum; the Ordinance says «exceeds pointwise by more than 30 %». NX follows the text. See Validation and limits.

Can I use a return period other than 475 years? No: the Ordinance prescribes the comparison at 475 years. Nominal life and use class of the structure are for information only.

My file does not import. Check that it has two numeric columns (period and acceleration) and increasing periods. The message tells you at which line it stops. Headers are skipped automatically.

The spectrum starts at 0.02 s. Appendix 1 requires Se(0.01 s): without that value the regularisation cannot be done.

What does «Comparison not applicable» mean? That 2·Tmax exceeds 1.1 s: according to note 1 of the Ordinance the comparison is not made.

The parameters service does not respond. Import a GeoStru PS report or enter the SLV row by hand (TR = 475 years).

How much does it cost? Everything is free except the Word report and the messages to the assistant. A failed operation is not charged.