Skip to content

MS3 spectrum

The file

The spectrum of the MS3 study is a two-column text: period T [s] and spectral acceleration. The reader detects on its own:

  • the separator: tab, semicolon, one or more spaces, or the comma between two numbers with a decimal point;
  • the decimal separator: comma or point;
  • the header lines (non-numeric), which it skips;
  • the lines with a single number, which it discards with a warning (in the San Severino file the second line is «0.04»).

Columns beyond the second are ignored. The periods must be strictly increasing: if they are not, the import stops and tells you which line. Choose the unit of the accelerations in the file (g or m/s²): if the maximum is suspect (more than 4 g, or less than 0.3 m/s²) a warning appears.

Preview and import

Once you choose the file, the preview shows the first lines as they are in the file and the first values read, with the number of points, the range of periods and the maximum. Press Import to write it into the project, or Cancel. The Microzone / spectrum name field goes into the report.

Import preview

Regularisation

As soon as it is imported, the spectrum is regularised according to Appendix 1 (formulas in Theory). The table shows TA, SAm, TV, SVm, TC, TB, Se(0.01 s), amax, TD and F0. The upper chart overlays the MS3 spectrum (black) and the regularised spectrum (red) with the verticals of TB, TC and TD; the lower one is the pseudo-velocity spectrum SV = SA·T/2π, always derived from SA.

MS3 spectrum, regularised spectrum and pseudo-velocity

Se(0.01 s)

Appendix 1 extrapolates amax from the value of the spectrum at 0.01 s. If the file does not have that point, the value is interpolated; if the spectrum starts after 0.01 s, the regularisation cannot be done and the app tells you.


Found an error on this page? Let us know or open a Pull Request.