Skip to content

Glossary

Terms and symbols used in GeoTheis NX, in alphabetical order. The formulas are explained in Theoretical background.

Note

The letter B has two meanings: in the step-drawdown test it is the coefficient of linear aquifer loss (s = BQ + CQ²); in a leaky aquifer it is Hantush's leakage factor. The context and units tell you which one applies.

Drawdown (s) — Difference between the static water level and the level measured during pumping, in m. In the step-drawdown test it is cumulative from the start of the test.

Critical drawdown (sc) — Drawdown in the well at the critical discharge, on the characteristic curve s = BQ + CQ². Without a step-drawdown test, you enter it as the known critical drawdown.

Residual drawdown (s′) — Drawdown remaining during recovery, measured from the static water level.

Stabilised drawdowns — Steady-state drawdowns in the well and piezometers, when the cone of depression no longer expands. They are used by Dupuit-Thiem.

Specific drawdown (s/Q) — Drawdown divided by discharge. In the step-drawdown test, s/Q = B + C·Q is a straight line.

Reliability — The program's assessment of each method: reliable, indicative, unreliable, to be verified. See Results.

Storage coefficient (S) — Volume of water released from an aquifer column of unit base area for a unit decline in head. Dimensionless, between 0 and 1. It is small in a confined aquifer (10⁻⁵–10⁻³) and approaches the effective porosity in an unconfined aquifer. It is derived from piezometers, not from the pumping well.

Well loss coefficient (C) — Coefficient of the quadratic loss CQ² in the step-drawdown test; in SI units, s²/m⁵; in Walton's classes, min²/m⁵. It increases as the well becomes clogged.

Aquifer loss coefficient (B) — Coefficient of the linear loss BQ in the step-drawdown test, in s/m².

Completion — How the well is constructed: drilling, casing (blank sections, screen, sump), annulus (gravel pack, cement seal, plugs), wellhead chamber, pump.

Cone of depression — Surface of the lowered water level around the well during pumping; it vanishes at the radius of influence.

Characteristic curve — The well's s(Q) curve, s = BQ + CQ², obtained from the step-drawdown test. It is used to select the critical discharge.

Type curve — The theoretical Theis W(u) or Hantush W(u, r/B) curve onto which the piezometer readings are superimposed.

Distance-drawdown — Method that uses the drawdowns in several piezometers at the same time, plotted against the logarithm of distance.

Leakage — Water yielded to the leaky aquifer by the semipermeable layer when the head falls.

Well efficiency (E) — Proportion of the drawdown due to the aquifer: E = BQ/(BQ + CQ²). It decreases as discharge increases; it equals 50 % at the discharge Q = B/C.

Confined aquifer (under pressure, artesian) — Aquifer enclosed between two impermeable layers; the static water level is above the top of the aquifer.

Unconfined aquifer (phreatic) — Aquifer whose water surface is at atmospheric pressure and falls during pumping.

Leaky aquifer — Aquifer beneath a semipermeable layer that supplies it by leakage; in GeoTheis NX it can be unconfined or confined (called “semi-unconfined” and “semi-artesian” in the desktop version).

Leakage factor (B) — B = √(T·c), in m, where c is the hydraulic resistance of the semipermeable layer. The larger B is, the less significant the leakage.

Fitting — Automatic fitting of the type curve to the readings by least squares (Levenberg-Marquardt), which gives T, S (and r/B) with 95 % confidence intervals.

Well function W(u) — Exponential integral of the Theis solution.

Dynamic water level — Water level in the well during pumping.

Static water level — Water level at rest, before pumping; in the Well tab it is an elevation in m a.s.l.

Head losses — Drawdown in the well divided into aquifer losses (linear, BQ, laminar flow) and well losses (quadratic, CQ², turbulent flow in the screen and gravel pack).

Permeability or hydraulic conductivity (K) — Seepage velocity under a unit gradient, in m/s; also displayed on screen in m/day. K = T/b (or T/H1).

Piezometer — Observation well or tube at a known distance from the pumping well, in which drawdown is measured without pumping. It is used to derive S and the radius of influence.

Allowable discharge — Discharge that the program proposes for operating the well: normally the optimum discharge, limited by the maximum tested discharge and the constraints on the dynamic water level. See Results.

Critical discharge (Qc) — Discharge above which well losses increase disproportionately. You select it on the characteristic curve; if you do not, the program proposes Q = B/C.

Known critical discharge — Qc and sc that you enter in the Test tab without a step-drawdown test (from nearby tests or the commissioning test), together with the assumed radius of influence, for single wells.

Operating discharge — Discharge that you confirm for the well; it feeds the report and the cone of depression.

Optimum discharge (Qott) — 0.9·Qc.

Specific capacity (Q/s) — Discharge per metre of drawdown: the inverse of specific drawdown.

Fully penetrating / partially penetrating well — Fully penetrating if the screen extends through the full thickness of the aquifer, partially penetrating if it extends through only part of it.

Single wells — Methods that estimate T and K from the critical pair (Qc, sc) alone and an assumed radius of influence, as if steady-state conditions applied. They give indicative values.

Step-drawdown test — Pumping at increasing discharge rates in steps of equal duration; it gives the characteristic curve, head losses, well efficiency and critical discharge.

Constant-rate test — Pumping at a fixed discharge with readings over time in the well and piezometers, usually followed by recovery; it gives T, S and R.

Match point — Point (W, u, s, t/r²) read by superimposing the data and the type curve; T and S are derived from it. In GeoTheis NX it is the result of a manual adjustment or a point imported from the desktop version.

Radius of influence (R) — Distance from the well at which the drawdown vanishes. Obtained from Thiem's straight line through the piezometers, from the transient radius R(t) = √(2.25·T·t/S), or assumed for single wells.

Well radius (rw) — Radius of the pumping well, in m (not the diameter).

Hydraulic resistance (c) — Thickness of the semipermeable layer divided by its vertical hydraulic conductivity, in s.

Recovery — Rise in the water level after the pump is stopped; t′ is the time since shutdown.

Aquifer thickness (b) — Top minus base of the confined or leaky aquifer: b = TI − SI.

Saturated thickness (H1) — In an unconfined aquifer, static water level minus base: H1 = LS − SI.

Impermeable base (SI) — Base of the aquifer.

Impermeable top (TI) — Upper boundary of the confined aquifer.

Transmissivity (T) — Discharge passing through a 1 m-wide strip of aquifer, over its full thickness, under a unit gradient: T = K·b (or K·H1), in m²/s; also displayed on screen in m²/day.

u — Dimensionless Theis variable, u = r²S/(4Tt). Cooper-Jacob is valid for u < 0.05.


Found an error on this page? Let us know or open a Pull Request