Theory overview¶
This page summarises the pumping test theory used by GeoTheis NX: aquifer types, steady and transient flow, methods for the constant-rate test and the step-drawdown test, head losses, radius of influence and single wells. The formulas are those of the calculation engine. How the program chooses and compares the methods is explained in Results; the glossary of symbols is in Glossary.
Notation: Q discharge, s drawdown, r distance from the well, t time since the start of pumping, t′ time since the pump stopped, T transmissivity, S storativity (storage coefficient), K hydraulic conductivity (permeability), b thickness of the confined aquifer, H1 saturated thickness of the unconfined aquifer, rw well radius, R radius of influence. The engine works in SI units (m, s, m³/s, m²/s, m/s); l/s, m³/h, minutes and per-day values are for display only.
Aquifer types¶
| Type (Well tab) | Description | Thickness used |
|---|---|---|
| Unconfined | water-table aquifer: the water surface is at atmospheric pressure and is lowered by pumping | H1 = static level − base |
| Confined | confined (artesian) aquifer: enclosed between two impermeable layers, the level rises above the aquifer top | b = top − base |
| Leaky, unconfined | below a semi-pervious layer that feeds it, with a free surface | b, as for the confined aquifer |
| Leaky, confined | below a semi-pervious layer that feeds it, under pressure | b, as for the confined aquifer |
Transmissivity is the discharge flowing through a 1 m wide strip of aquifer, over its full thickness, under a unit gradient: T = K·b in a confined aquifer, T = K·H1 in an unconfined aquifer. Storativity S is the volume of water released by a column of unit base area for a unit decline in head. In a confined aquifer S is small (typically 10⁻⁵–10⁻³) because the water comes from the compressibility of the water and of the skeleton; in an unconfined aquifer it comes from the drainage of the pores and S approaches the effective porosity (typically 10⁻²–0.3).
In a leaky aquifer the semi-pervious layer releases water to the aquifer when the head drops (leakage). Its hydraulic resistance c = thickness/vertical permeability of the semi-pervious layer defines the leakage factor B = √(T·c).
Steady and transient flow¶
During constant-rate pumping the cone of depression widens over time: this is transient flow, described by Theis, Cooper-Jacob and Hantush, which give T and S. If the cone stops widening (recharge, leakage, recharge boundaries) the drawdowns stabilise: this is the steady state of Dupuit-Thiem, which gives T (or K) and the radius of influence R but not S.
Assumptions common to the analytical methods: homogeneous, isotropic aquifer of constant thickness and infinite extent; horizontal flow towards a fully penetrating well; constant discharge; well of negligible radius. Where your data depart from them, the program still calculates and says so with a warning (see Limits).
Constant-rate test¶
Theis (1935)¶
Transient-flow solution in a confined aquifer:
W(u) is the well function (the exponential integral E1). The engine calculates it with the Abramowitz & Stegun series (5.1.11 for u ≤ 1, continued fraction 5.1.22 for u > 1), with a relative error of the order of 10⁻¹⁵.
The classic method overlays, on a log-log scale, the s – t/r² readings on the W(u) – 1/u type curve and reads a match point (W, u, s, t/r²):
GeoTheis NX performs the same overlay with an automatic least-squares fit (Levenberg-Marquardt) on the logarithms of the drawdowns of each piezometer, and gives T and S with the 95 % confidence interval. The match point remains available as an adjustment (see Results).
Cooper-Jacob (1946)¶
For small u the series of W(u) reduces to its first two terms, W(u) ≈ −0.5772 − ln u, and the drawdown grows linearly with the logarithm of time:
From the s – log10 t straight line, with Δs the drawdown per log cycle and t0 the time at which the line gives s = 0:
The approximation holds for u < 0.05. The program automatically uses the final segment with t > 11.25·t0 (i.e. u < 0.05) and recalculates t0 until the selection no longer changes. On the pumping well T can be derived, S cannot: the well losses and the uncertain effective radius distort the intercept.
Recovery (Theis 1935)¶
After the pump stops the water level recovers. By superposition (pumping that continues plus an equal injection from the stop), the residual drawdown s′ is:
with Δs′ the residual drawdown per log cycle of t/t′. Recovery gives T but not S. If the line reaches s′ = 0 at a t/t′ very different from 1, the aquifer has recharge (t/t′ > 1) or an impermeable boundary or a finite volume (t/t′ < 1).
Hantush-Jacob (1955)¶
In a leaky aquifer, with the semi-pervious layer without storage:
At early times the curve follows Theis; at late times leakage flattens it towards the steady value W(0, r/B) = 2·K0(r/B). The engine calculates W(u, r/B) by numerical integration (Gauss-Kronrod), not with Hantush's table. With a match point: T = Q·W/(4π·s), S = 4·T·u·(t/r²), B = r/(r/B), c = B²/T. The program applies Hantush only if the aquifer is leaky; if the fit brings r/B below 10⁻³, leakage is not visible in the data and the result coincides with Theis.
Dupuit-Thiem, steady state (Dupuit 1863; Thiem 1906)¶
With the stabilised drawdowns of the piezometers:
where Δs (or ΔZ) is the change per log cycle of distance on the s – log10 r (or Z – log10 r) line of the piezometers, and R is the distance at which the line gives s = 0. With a single piezometer the line passes through the well, and the result is indicative.
Distance-drawdown¶
On the same s – log10 r line, but with the piezometer drawdowns at the same time t of pumping (Cooper-Jacob in distance): T = ln10·Q/(2π·Δs), r0 where s = 0, S = 2.25·T·t/r0². At least two piezometers at different distances are needed, and u must be small even at the farthest piezometer.
Step-drawdown test¶
The well is pumped at increasing discharges Q1, Q2, … in steps of equal duration; for each step the drawdown at the end of the step is read (cumulative from the start of the test).
Head losses and Jacob's equation (1947)¶
The drawdown in the well is the sum of a linear aquifer loss (laminar flow, BQ) and a quadratic well loss (turbulent flow in the screens, in the gravel pack and near the well, CQ²):
B and C are the intercept and the slope of the specific drawdown s/Q versus Q line, by least squares on the valid steps. s/Q (or its inverse Q/s, the specific capacity) tells how much the well «yields».
The efficiency of the well is the share of drawdown due to the aquifer:
and it decreases as the discharge increases. The program calculates it at the reference discharge given in the project, otherwise at the optimal discharge.
Critical discharge and optimal discharge¶
The critical discharge Qc is the discharge beyond which the well losses grow disproportionately with respect to the benefit: you choose it on the characteristic curve s(Q). If you do not choose it, the program proposes Q = B/C, the discharge at which the well losses equal the aquifer losses (E = 50 %). The optimal discharge is Qott = 0.9·Qc, and the critical drawdown sc is that of the curve at Qc.
Well condition (Walton 1962)¶
Classes based on the coefficient C expressed in min²/m⁵:
| C (min²/m⁵) | Well condition |
|---|---|
| ≤ 0.5 | properly designed and developed |
| 0.5–1 | mild deterioration due to clogging |
| 1–4 | severe deterioration or clogging |
| > 4 | difficult to restore the well to its original condition |
Rorabaugh (1953)¶
Generalises Jacob with a free exponent:
estimated by least squares on the drawdowns (with n = 2 Jacob is recovered). At least three steps are needed; with three the curve passes through the points. Values of n outside 1.5–3.5 do not have Rorabaugh's physical meaning and the program flags this.
Distance methods on the steps¶
With piezometers, the end-of-step drawdowns also give:
- Thiem distance line for each step: s versus log10 r on the piezometers, T = ln10·Q/(2π·Δs), K = T/b (or T/H1 in an unconfined aquifer), R where s = 0;
- Dupuit-Thiem per step: the pair of readings well–P1 or P1–P2 as in steady state;
- Cooper-Jacob on the test stations: s/Q versus log10 t on the steps, T = 2.30/(4π·Δ(s/Q)), S = 2.25·T·t0/r².
The end-of-step drawdowns are not at steady state: these results are indicative, and the last one never enters the proposal.
Radius of influence¶
The radius of influence R is the distance at which the drawdown becomes zero. GeoTheis NX derives it, in order of preference:
- from the Thiem line on the stabilised drawdowns of the piezometers (s = 0);
- from the Cooper-Jacob transient radius at the end of pumping, if S is known:
- from the Thiem distance line on the steps (indicative).
R(t) grows with the pumping duration: it is not a property of the aquifer but of the state of the test. In the single wells R is not calculated: it is an assumed value that you enter.
Single wells¶
When there is only the well, the single wells methods use the critical pair (Qc, sc) as if it were a steady state, with an assumed radius of influence R. The pair comes from the step-drawdown test or, without steps, from the known critical discharge entered in the Test tab. The results are indicative estimates: they do not replace a test with piezometers. Leaky aquifers are not handled.
Fully penetrating well (Celico)¶
with H2 = H1 − s.
Partially penetrating well¶
If the screen crosses only part of the aquifer, the flow lines also converge vertically towards the screen and the drawdown in the well is larger than that of a fully penetrating well. The formulas correct for the geometry; L is the screen length.
Unconfined aquifer (Chiesa), with a the distance between the bottom of the screen and the base:
Confined aquifer (Chiesa), according to the screen position (D distance from the top to the start of the screen):
- type A, screen detached from the top and not reaching the base: T = Q/(2π·s)·[ln(R/(2b)) + (b/L)·ln(2L/rw)];
- type B, screen attached to the top, shorter than the thickness, and type C, screen detached from the top and reaching the base: T = Q/(2π·s)·[ln(R/rw) + ξ/2], with ξ from Chiesa's table as a function of b/rw and L/b;
- K = T/b.
In a confined aquifer the program also calculates the specific formulas (K from which T = K·b, or T from which K = T/b):
| Method | Formula |
|---|---|
| Kozeny (1933) | K = Q/(2π·s·L)·ln(R/rw) / [1 + 7·√(rw/(2L))·cos(π·L/(2b))] |
| Infinite thickness (Babushkin) | K = Q/(2π·s·L)·ln(2L/rw) |
| Halek | K = Q/(2π·s·L)·[ln(4(L/rw)/(L/R + √(1 + L²/R²))) + 1 − (R/L)(1 − √(1 + L²/R²))] |
| Zangar | K = Q/(2π·s·L)·ln(L/rw) |
| Muskat | T = Q/(2π·s)·[(b/2L)·(2·ln(4b/rw) − ln Γ) − ln(4b/R)] |
| Girinski | K = Q/(2π·s·L)·ln(1.6·L/rw), only with L/rw ≤ 5 |
| «L/b − L/2r» | T = Q/(2π·s)·ln((2/L)·(L/2rw) + 0.2/b) |
Warning
Five formulas are marked to be checked against the reference text and remain as in the desktop program: Halek (reconstructed, not compared with the text), Muskat (value of ln Γ), Girinski (the L/rw ≤ 5 limit excludes it for any real screen), «L/b − L/2r» (the argument of the logarithm is not dimensionless, so T depends on the unit of measurement) and the ξ/2 term of types B and C. Use them only for comparison.
Cone of depression¶
The cone drawn in the well section uses the design values in use:
- with T, S and the pumping duration, the Theis curve (Hantush if the value comes from Hantush) at the end of pumping, from rw to R(t);
- otherwise Thiem (confined aquifer) or Dupuit (unconfined aquifer) up to the design radius of influence R.
Validity of the results¶
- Theis and Cooper-Jacob assume a confined aquifer. In an unconfined aquifer they hold as long as the drawdown is small compared with the saturated thickness: the program does not apply Jacob's correction s′ = s − s²/(2H) nor Neuman's model for delayed yield.
- Hantush does not account for the storage of the semi-pervious layer.
- Not modelled: wellbore storage and skin, recharge or impermeable boundaries, anisotropy, variable discharges other than steps, interference of multiple wells.
The summary of the limits is in Results → Limits; the checks on the calculation code are in Validation.
References¶
- Theis C.V. (1935). The relation between the lowering of the piezometric surface and the rate and duration of discharge of a well using ground-water storage. Transactions of the American Geophysical Union, 16(2), 519–524.
- Cooper H.H., Jacob C.E. (1946). A generalized graphical method for evaluating formation constants and summarizing well-field history. Transactions of the American Geophysical Union, 27(4), 526–534.
- Jacob C.E. (1947). Drawdown test to determine effective radius of artesian well. Transactions ASCE, 112, 1047–1070.
- Hantush M.S., Jacob C.E. (1955). Non-steady radial flow in an infinite leaky aquifer. Transactions of the American Geophysical Union, 36(1), 95–100.
- Hantush M.S. (1956). Analysis of data from pumping tests in leaky aquifers. Transactions of the American Geophysical Union, 37(6), 702–714.
- Hantush M.S. (1964). Hydraulics of wells. In: Advances in Hydroscience, vol. 1, Academic Press.
- Rorabaugh M.I. (1953). Graphical and theoretical analysis of step-drawdown test of artesian well. Proceedings ASCE, 79, separate 362.
- Walton W.C. (1962). Selected analytical methods for well and aquifer evaluation. Illinois State Water Survey, Bulletin 49.
- Thiem G. (1906). Hydrologische Methoden. Leipzig, J.M. Gebhardt.
- Dupuit J. (1863). Études théoriques et pratiques sur le mouvement des eaux dans les canaux découverts et à travers les terrains perméables. 2nd ed., Paris, Dunod.
- Kozeny J. (1933). Theorie und Berechnung der Brunnen. Wasserkraft und Wasserwirtschaft, 28.
- Kruseman G.P., de Ridder N.A. (1994). Analysis and Evaluation of Pumping Test Data. 2nd ed., ILRI Publication 47, Wageningen.
- Chiesa G. Idraulica delle acque di falda. Palermo, Flaccovio.
- Celico P. Prospezioni idrogeologiche. Napoli, Liguori.
- Abramowitz M., Stegun I.A. (1964). Handbook of Mathematical Functions. National Bureau of Standards, Applied Mathematics Series 55.
- Marquardt D.W. (1963). An algorithm for least-squares estimation of nonlinear parameters. Journal of the SIAM, 11(2), 431–441.
- Moré J.J. (1978). The Levenberg-Marquardt algorithm: implementation and theory. Lecture Notes in Mathematics 630, Springer.
Found an error on this page? Let us know or open a Pull Request.