Skip to content

Quick start (5 minutes)

You get to the results and to the report preview with the CELICO example, which the program has ready: a complete well in a confined aquifer with a step-drawdown test, a constant-rate test with recovery and two piezometers. You do not have to type any data. With your own data the steps are the same: you find them in full in the Workflow.

1. Open the example

Open nx.geostru.ai/geotheis. In the top bar open the File menu: under Open… there is the Examples with tests list. Choose CELICO, the first one.

If the project on screen has changes that are not in a file, the program tells you: The project has changes that are not in a file: if you continue, they will be lost. Choose Save first or Continue without saving.

The app goes back to the Well tab with the strip Example «CELICO» opened: it is a desktop program file, read as a .wtax. Below it, More import notes lists what the desktop file reader noticed: read them when you open one of your own .wtax files.

Note

The examples are the files of the GeoTheis desktop program. The CELICO data are built to test the calculation; they do not describe a real aquifer.

2. Look at the well

In the Well tab scroll through the panels on the left; on the right the Well section is already drawn.

  • Site and coordinates: CELICO has no geographic position, so the well is not on the map. With your own well, click the map at the well location.
  • Stratigraphy: the layers from ground level downwards.
  • Well and aquifer, Aquifer and levels tab: aquifer type Confined, penetration Fully penetrating, elevations in m a.s.l. (ground level 98, static level 93, aquifer top 91, base 84). In the Calculation scheme tab the Well radius rw = 0.5 m.
  • Piezometers: P1 at 23.5 m and P2 at 42.4 m from the well axis.

Above the section, move the two sliders Discharge Q and Time t: the cone of depression moves with them.

Press Test at the bottom of the page.

3. Look at the test

The Test tab has two panels:

  • Step-drawdown test: 3 steps, one row per step with the time, the discharge and the drawdowns in the well and in the piezometers;
  • Constant rate and recovery: the Test discharge, the Steady-state drawdowns, the Pumping and Recovery readings.

Discharges are in l/s and times in h:mm:ss. To see the CELICO discharges in m³/h, as in the desktop file, change Discharges in: it only changes the display. Details in Tests.

Press Results.

4. Read the results

The Results tab calculates by itself every method the data allow.

  1. In Test results read the two columns: Methods calculated and Not applicable to the data, each with its reason.
  2. In the Design value panel the program proposes Theis (fitting automatico), Theis with automatic fitting, with the reasoning: it agrees with Cooper-Jacob. The radius of influence R = 76.5 m comes from the Thiem line on the piezometers.
  3. In the Allowable discharge panel you find Qc, Qott and the proposed discharge. In CELICO the proposal is lower than 0.9·Qc because the pumping level must not fall below the top of the confined aquifer: the reasoning says so.
  4. The Comparison of methods flags that the step-test methods give much higher T than the constant-rate methods. Open the method tabs to see the charts.

If the proposal convinces you, press Confirm the proposal. Everything you do in this tab is free. The tab is explained in Results.

Press Report.

5. Look at the report preview

The Report tab shows what goes into the document and, below, the Preview: it is the same text as the Word file, with an indicative layout. The preview is free.

Generate Word downloads the report and uses credits; Well DXF downloads the well section as DXF, also for credits. See Report.

6. Save

The project is in the session and expires after 30 minutes of inactivity. To keep it use File → Save as…: you download a .geotheisnx file that you reopen with File → Open…. Alternatively, save it to GeoDropbox. See Files and GeoDropbox.

Next steps

For your own well start from File → New project and follow the Workflow. The fields of the Well tab are described in Well.


Found an error on this page? Let us know or open a Pull Request.