Skip to content

Well

The Well record describes the structure and its location: position and coordinates, soils encountered, aquifer type and elevations, well geometry, completion and piezometers. On the left there are four panels, in this order:

  1. Site and coordinates
  2. Log
  3. Well and aquifer, with four tabs: Aquifer and levels, Calculation scheme, Completion, Job
  4. Piezometers

On the right, the Well section is redrawn as you type.

Only a few data are required for the calculation: the aquifer type, the aquifer elevations, the well radius and the distance of each piezometer. The other data are used for the drawing, the report and the allowable discharge checks.

How data is saved

There is no “Save” button in the panels: each field is saved automatically in the session. An option, checkbox or drop-down list is saved immediately; text is saved after a short pause in typing. Next to the panel title you can see the status: Saving…, Saved · hh:mm or Not saved.

  • Numbers can be entered with a comma or a decimal point.
  • A value that is not a number remains in red with Not a readable number: not saved.
  • Thicknesses, distances, diameters, radius, depths and lengths cannot be negative: a negative value remains in red with Cannot be negative: not saved. Elevations in m a.s.l. can be negative.
  • An empty field means that no data has been entered, not zero.

Warning

Saved means saved in the session on the server, which expires after 30 minutes of inactivity. To keep the project, save it to a .geotheisnx file or to GeoDropbox: see Files and GeoDropbox.

Site and coordinates

The panel places the well on the map and gives its coordinates in all systems. The position is not used in the parameter calculation: it is used for the report (map, coordinates, nearby wells), piezometer distances and links with the other NX apps.

Map

Above the map:

  • Search a place (town, street, locality) + Search centres the map on the place found. The well does not move: Map centred on …. The well has not moved: click the exact point to place it.
  • GPS position places the well using the device GPS and reports the stated accuracy (±… m).
  • A click on the map selects what clicking does: navigation only, places the well or places the piezometer (with a drop-down list for the piezometer to be placed).
  • Map and Satellite change the base map.

Until the well is on the map, clicking is already in places the well mode; after the first click it returns to navigation only, so you do not move the well by mistake. The well and piezometers can also be dragged on the map.

The legend below the map shows the well, piezometers, ISPRA registered wells, the dashed circle for the nearby-well search radius and, when available, the radius of influence circle: Project R = … m, with its origin (confirmed, proposed by the program or assumed).

Position, municipality and elevation

When the well is on the map, the Well panel shows its position in sexagesimal degrees and the system in which the coordinates were entered. The program then proposes:

  • Municipality, Province and Locality from the Nominatim service (OpenStreetMap), only in empty fields. If the point is in another municipality, The point is in … appears with the Use button. All three fields can also be entered manually.
  • The Ground elevation from the DTM: TINITALY (INGV) at 10 m; if it does not respond, Copernicus GLO-90 at 90 m, which is less accurate.

Below the DTM elevation is the Ground level elevation (project data), namely the Ground level field on the Aquifer and levels tab, with the difference from the DTM. The DTM elevation is only a proposal: the project survey data takes precedence and changes only if you press Use the DTM elevation. If a service does not respond, Retry elevation and municipality repeats the request.

Note

The DTM elevation is an average value for the model cell. A survey is required for levelling.

Coordinates to enter

To place a point from coordinates:

  1. Point: the Well or one of the piezometers;
  2. System: one of the systems in the table below;
  3. Easting (m) and Northing (m), or Longitude and Latitude for geographic systems;
  4. Place.
System EPSG
WGS84 geographic 4326
WGS84 / UTM zone 32N, 33N, 34N 32632, 32633, 32634
ETRS89 / UTM zone 32N, 33N, 34N 25832, 25833, 25834
RDN2008 / UTM zone 32N, 33N, 34N 6707, 6708, 6709
Roma40 / Gauss-Boaga West zone, East zone 3003, 3004
ED50 / UTM zone 32N, 33N, 34N 23032, 23033, 23034
Roma40 (Monte Mario) geographic, Greenwich 4265
ED50 geographic 4230

For geographic systems, you can enter decimal degrees or degrees, minutes and seconds (for example 38°04'08" N). The source system is retained in the project and reported in the report.

The program checks the coordinates before placing the point:

  • Easting greater than Northing: they appear to be swapped. In Italy, Northing ranges from 4 to 5.2 million metres.
  • The point is outside Italy: check the coordinate system and digits.
  • The point is more than 9° from the central meridian of the system: the conversion loses precision (beyond one centimetre).

The well in all systems

The table lists the well in every system, with East / Lon, North / Lat and the datum Transformation used. The systems for the zone containing the well are listed first; the others are under Neighbouring zones and other systems, marked outside zone or beyond the precision limit.

The conversion uses 7 EPSG parameters: the error is of the order of one metre, up to a few metres (Sicily and Sardinia have their own parameters; ED50 up to approximately 10 m). The official IGM conversion uses grid files.

Piezometer positions

For each piezometer, the table compares the distance entered in the Piezometers panel (r entered) with the distance derived from the coordinates (r from coordinates), together with the Azimuth from north and the Status:

Status Meaning
not on the map the piezometer has no coordinates
well missing the piezometer is on the map but the well is not: place the well first
r to complete no distance had been entered: the program enters it from the coordinates
consistent the two distances differ by no more than 1 m
choose the two distances differ by more than 1 m: you choose which one applies

When the status is choose, you have two buttons:

  • Use r from coordinates: the piezometer distance becomes the calculated distance;
  • Move to the entered r: the piezometer moves on the map to the entered distance, at the same azimuth.

Remove from the map removes the piezometer coordinates; the entered distance remains. An entered distance is never overwritten without your choice.

A piezometer can be placed in three ways: click the map in places the piezometer mode, enter coordinates in Coordinates to enter, or use From distance and azimuth: select the piezometer, enter Distance from well (m) and Azimuth from north (°) and press Place. Distances and azimuths are calculated on the WGS84 ellipsoid (Vincenty formulae).

Registered wells nearby

The Registered wells nearby (ISPRA, Law 464/84) panel searches for boreholes in the national archive within the selected Radius (m) (from 50 to 2,000 m, 500 m on opening). The search starts when you place the well; Search repeats it. The table shows Distance, Work, Depth, Water, Log, Municipality and the link to the ISPRA Record.

Warning

The Law 464/84 archive is incomplete: “no registered wells” does not mean “no wells”. Wells not included in the archive can be found in regional land registers and geoportals.

Check against a second source

In Check against a second source, enter the coordinates of the same well obtained from another source (report, photo GPS, land register), with their System and a Threshold (m) (10 m on opening), and press Compare. The program states whether the two positions are within the threshold. If the difference is between 40 and 300 m, which is typical of the difference between datums (Roma40 or ED50 versus WGS84), it adds that one of the two coordinates may have been entered in the wrong system. The comparison does not modify the project.

Links with the other NX apps

Site dossier with Atlante, at the top of the panel, opens Atlante NX at the well location: geology, constraints, hazards and maps with references.

If you open GeoTheis NX from another NX app (Atlante, Hydrogeo, Maps) with a point, a banner appears proposing the position: Use this point or Ignore. If the well already has a different position, the banner states how many metres away the new point is. The point is never applied automatically.

Log

Layers are entered from ground level downwards, one per row, with their thickness. The log is not used in the calculation: it is used for the section drawing and the report.

Column Unit What you enter
Soil — the soil from the catalogue; determines the hatch pattern in the drawing
Description — free text (up to 400 characters)
Thickness m layer thickness, non-negative
From – to m depth to the top and bottom of the layer: calculated by the program from the thicknesses
Colour — tick the checkbox to use a custom colour instead of the soil hatch pattern

The soils in the catalogue are: Clean sand, Silty sand, Clayey sand, Silty-clayey sand, Gravelly sand, Sandy gravel, Gravel, Silt, Sandy silt, Clayey silt, Sandy-clayey silt, Clay, Organic soils, Rock, Other.

Add layer adds a row at the bottom; the × on the right removes it. At the top of the panel you can see the number of layers and the total thickness.

If you open a desktop program file containing a soil that is not in the catalogue, the row shows from desktop: “…” and the soil is Other: select the closest soil so that the drawing uses the correct hatch pattern.

Well and aquifer

The panel has four tabs. It opens on the last tab you used.

Aquifer and levels

Aquifer type determines which calculation methods apply. Until you select it, The aquifer type has not yet been selected: it is required to determine which calculation methods apply. appears, and the methods in Results assume a confined aquifer.

Option Meaning
Unconfined phreatic: the water surface is at atmospheric pressure and falls during pumping
Confined artesian (confined): enclosed between two impervious layers, the water level rises above the top of the aquifer
Leaky, unconfined beneath a semi-pervious layer that feeds it; free surface (“semi-unconfined” in the desktop version)
Leaky, confined beneath a semi-pervious layer that feeds it; under pressure (“semi-artesian” in the desktop version)

The Hantush method is calculated only for a leaky aquifer. See Methods.

Well penetration:

  • Fully penetrating: the screens extend through the full aquifer thickness;
  • Partially penetrating: the screens extend through only part of it; Screen – base (TSI) and, for confined aquifers, Blank between screen and base (LC) are required on the Calculation scheme tab.

Construction: Drilled or Dug (large diameter). This changes the well drawing.

Elevations, in m a.s.l., as in the desktop program:

Field Abbreviation When it appears What it is
Ground level PC always ground elevation at the well
Well head QTF always elevation of the top of the casing
Static water level LS always elevation of the water level at rest
Impervious top TI confined aquifer (including leaky) or not selected elevation of the top of the confined aquifer
Impervious base SI always elevation of the aquifer base
Top of semi-pervious layer TSP leaky aquifers elevation of the top of the semi-pervious layer
Bottom of semi-pervious layer LSP leaky aquifers elevation of the base of the semi-pervious layer

Only the elevations required for the selected aquifer type are shown; the others remain saved. From the elevations, the program derives:

\[ H_1 = LS - SI \qquad b = TI - SI \]

where H1 is the saturated thickness (unconfined aquifer) and b is the confined aquifer thickness. The elevations are also used for the allowable discharge checks: with a confined aquifer, the dynamic water level must not fall below the top. See Results.

Calculation scheme

The scheme is the geometry used by the formulae for single wells, as in the desktop program. It remains an explicit item of data, separate from the drawn completion: the two may not coincide.

Field Abbreviation Unit When it appears What it is
Well radius rw m always radius used in the calculation (not the diameter)
Total depth — m always from ground level, for the drawing
Blank between head and screen LFC m always length of blank casing above the screen, measured from the well head
Screen length LTF m always length of the screened section
Screen – base TSI m partially penetrating well distance between the bottom of the screen and the impervious base
Blank between screen and base LC m partially penetrating well in a confined aquifer (including leaky) blank section below the screen

The well radius is also used for drawdown in the well and the cone of depression.

Propose completion from scheme fills in the blank casing, screen and drilling on the Completion tab based on the scheme; annulus, well chamber, pump and levels remain unchanged. The ground level elevation, well head elevation and screen length are required. If casing already exists, the program asks for confirmation: The current casing and drilling will be replaced by those proposed by the scheme. → Replace or Cancel.

Completion

The completion describes the well as built, for the drawing and the report. Depths are in m from ground level, positive downwards; diameters are in mm. Each table has its own Add section button (or Add level) and a × to remove the row.

Drilling: one section for each drilling diameter.

Column Unit
From, To m from ground level
Diameter mm

Casing: blank, screens, sump: sections of the casing string, including multiple screens.

Column Unit Notes
Type — Blank, Screen or Sump
From, To m from ground level
Outer Ø mm outside diameter of the casing
Wall mm wall thickness
Material — free text
Screen type — only for Screen sections
Slot mm screen aperture, only for Screen sections

Annulus: the space between the borehole and the casing.

Column Unit Notes
Type — Grout, Clay seal or Gravel pack (proposed for a new row)
From, To m from ground level
Material or note — free text

Well chamber and Pump are enabled with their checkboxes; if unticked, the fields remain but are not used.

Well chamber Unit
Bottom depth m
Diameter mm
Pump Unit Notes
Intake depth m from ground level used in the allowable discharge check
Rated flow l/s
Power kW
Description — free text

Intake depth is not only drawing data: the proposed allowable discharge keeps the intake at least 1 m below the dynamic water level. See Results.

Measured levels: water level measurements in the well, for the drawing and the report.

Column Unit Notes
Type — Static or Dynamic
Depth m from ground level
Date — free text
Note — free text

Note

The static water level used in the calculation is the Static water level elevation (LS) on the Aquifer and levels tab, in m a.s.l. The measured levels in the completion are used for the drawing and the report.

Job

The job data are included in the report; none are used in the calculation.

Field Notes
Client
Project or well use for example irrigation, industrial, water supply
Test date free text
Contractor
Responsible engineer
Description free text
Notes free text

Piezometers

One piezometer per row. The distance r from the well axis is the only piezometer data used in the calculation; elevations and screen are used for the drawing.

Column Unit What it is
Name — the name shown in tables, charts and the report (up to 40 characters)
Distance m distance r from the well axis, non-negative
Ground level m a.s.l. ground level elevation at the piezometer
Head elevation m a.s.l. elevation of the top of the piezometer
Depth m piezometer depth
Screen from, Screen to m screened section
Map — placed if the piezometer has coordinates, otherwise —

Next to the name is an identifier (P1, P2…) assigned automatically by the program: test readings are linked to this identifier, not to the table row. If you leave the name empty, the identifier is used.

Add piezometer adds a row. The × removes the piezometer after confirmation: Remove …? Its test readings will also be lost. The readings of the other piezometers remain unchanged.

The map position is set in the Site and coordinates panel. If the well and piezometer are on the map, the distance is derived from the coordinates only when you have not entered it yourself; otherwise you choose which one applies (see Piezometer positions).

Without piezometers, No piezometers: the test is analysed using the well alone. appears. From the pumping well alone, T can be derived, but not S reliably. See Methods.

Data to check

After every save, the program checks that the data in the Well and aquifer panel are consistent. If something is inconsistent, the Data to check banner appears at the top of the panel. This is not a rejection: the data remain saved and the calculation proceeds.

Warning When
The static water level is … m above ground level: is this a flowing artesian well? Otherwise, check the elevations. LS > PC
The impervious base is at the same elevation as the static water level or higher: the aquifer would have no saturated thickness. Check the elevations. SI ≥ LS
The top of the aquifer is not above the base: the thickness b = TI − SI would be zero or negative. Check the elevations. confined aquifer, TI ≤ SI
The top of the aquifer is above ground level: check the elevations. non-unconfined aquifer, TI > PC
The top of the semi-pervious layer is not above its base: check the elevations. leaky aquifer, TSP ≤ LSP
The well radius is zero: it is required for drawdown in the well and the cone of depression. rw = 0
Well radius of … m: is this the radius, not the diameter? (in metres) rw > 5 m
The well head is more than 5 m below ground level: check the elevations. QTF < PC − 5 m

The same checks for readings appear in the Test record. See Tests.

Well section

On the right of the record, the Well section is generated on the server after every save: log with hatch patterns, drilling, casing with screens and sump, annulus, well chamber, pump, levels, aquifer top and base, semi-pervious layer, piezometers and cone of depression. Piezometers are projected onto the section plane at their distance from the well; the well width is not to scale and the note below the drawing states by how much.

Controls:

  • Discharge Q and Time t: two sliders that move the cone of depression. They work when T and S (or the test results) are available.
  • Distances: Log or Linear scale for distances from the well.
  • Scroll wheel to zoom, drag to pan; Fit (or double-click the drawing) returns to the full view.
  • PNG: image of the section, free of charge.
  • DXF: the section in DXF format, in metres, with layers. This uses credits; if the DXF is not generated, no charge is made.

The cone is drawn using the current project values and the operating discharge, as explained in Results.


Found an error on this page? Let us know or open a Pull Request.