Test

The Test tab collects the pumping test measurements: the step-drawdown test, the constant-rate test with recovery, the stabilised drawdowns and, if you do not have a step-drawdown test, the well's known critical discharge. Every value you enter is saved automatically; the Results are updated with the new data.

The tab has two panels:

  1. Step-drawdown test, with the panel for pasting steps and the Known critical discharge (without step-drawdown test) section;
  2. Constant rate and recovery, with the test discharge, stabilised drawdowns, pumping readings and recovery readings.

You do not need both tests. The method catalogue explains which methods are calculated from which data.

Note

Piezometers are entered on the Well tab (name and distance r from the well axis): see Well. Each piezometer adds an s name column to all the tables on this tab; hover over the heading to see its distance. If you remove a piezometer, its readings are removed too.

Units, times and numbers

At the top of each panel, choose how to read and enter the tables:

Control Choices Default
Times in h:mm:ss, s, min, h h:mm:ss
Discharges in l/s, m³/h, l/min, m³/s l/s

This is a display preference, not project data: it applies to this browser and is remembered. When you change it, the program first saves what you have entered, then reloads the page with the converted values. Calculations always use seconds and m³/s.

Rules common to all tables:

  • Times. Enter them as 1:30:00, 90 min, 2h or as a number in the selected unit. 8:20 means 8 h 20 min (clock convention, not minutes and seconds). The abbreviations 1h30m15s, 1h 30', 45 min, 90 s, 2 g or 2d, and 30" for seconds are also accepted. With Times in set to h:mm:ss, a number without a unit means minutes.
  • Drawdowns in m, positive downwards. An empty cell means no measurement was taken, not zero.
  • Numbers. Both decimal commas and decimal points are accepted; the typographic minus sign «−» and exponential notation (1,2E-03) are also accepted.
  • A completely empty row is not saved.

A value that cannot be parsed remains on screen marked in red and is not saved: the reason appears below the field (Not a readable number: not saved. or Cannot be negative: not saved.). Discharges, critical drawdown and assumed radius cannot be negative; a negative time cannot be parsed.

Step-drawdown test

One row per step: the end-of-step reading, with the time since the start of the test and the cumulative drawdowns (those measured at the end of the step relative to the static water level, not the increment for that step alone).

Column Unit Meaning
# — step number
Date text reading date, free text (up to 40 characters); not used in calculations
Time Times in unit time from the start of the test to the end-of-step reading
Discharge Discharges in unit step discharge; non-negative
s well m drawdown in the pumping well at the end of the step
s piezometer m drawdown in the piezometer at the end of the step (one column per piezometer)
Assumed R (m) m optional: step radius of influence read from the s – log r graph; used by distance-drawdown on steps when there is only one piezometer; does not follow the table units

Add step adds a row; the × on the right removes it. Paste from Excel or CSV opens the panel described below.

A step is valid if both its discharge and well drawdown are positive. Only valid steps are used for the characteristic curve:

  • with 2 valid steps at different discharges, B and C are calculated (Jacob's characteristic curve);
  • with 3 or more, Rorabaugh is also calculated (free exponent n);
  • piezometer drawdowns are used by distance-based step methods and test stations.

Time is only used by Cooper-Jacob for test stations. The critical discharge is not entered here: it is selected on the characteristic curve in the Results.

Tip

Enter the steps in increasing discharge order, as they were performed. If the datalogger records one reading per minute, do not copy them manually: paste them with Group readings into steps and the program keeps the last reading at each discharge.

Known critical discharge (without step-drawdown test)

If there is no step-drawdown test but you know the well's critical discharge (from tests in nearby areas or from commissioning), enter it here together with its critical drawdown. The single wells method derives T and K from the well geometry, Qc and sc, and the assumed radius of influence.

Field Unit Meaning
Critical discharge Qc Discharges in unit declared critical discharge
Critical drawdown sc m drawdown in the well at the critical discharge
Assumed radius of influence R m radius of influence to assume; also used for single wells in the step-drawdown test

All three values are required. They are declared values, not measured ones: single wells use them as steady-state conditions and give indicative values; the report states that Qc and sc were supplied by you. With a known critical discharge, the program also proposes the allowable discharge (0.9·Qc): see Allowable discharge.

The badge next to the title shows the status:

  • used without steps: there are no valid steps, so the known critical discharge is used;
  • not used: the test applies: there is at least one valid step. The critical discharge from the step-drawdown test, selected on the s(Q) graph in the Results, applies. Critical discharge Qc and Critical drawdown sc remain saved but read-only; Assumed radius of influence R remains editable, because single wells also need it with a step-drawdown test.

Warning

Single wells are not calculated for a leaky aquifer, or if you have not specified on the Well tab whether the well is fully penetrating or partially penetrating. The allowable discharge from the known critical discharge, however, is still proposed.

Constant rate and recovery

Test discharge and stabilised drawdowns

Field Unit Meaning
Test discharge (Q) Discharges in unit constant pumping discharge; non-negative
Stabilised drawdowns → s well m steady-state drawdown in the well
Stabilised drawdowns → s piezometer m steady-state drawdown in each piezometer
Assumed radius of influence (m) m for steady-state Dupuit-Thiem without piezometers; not used when piezometers are present

Without a positive Test discharge, no constant-rate method is calculated, even if readings are present. Stabilised drawdowns (steady state, for Dupuit-Thiem) are used by the steady-state Dupuit-Thiem method and to derive the radius of influence from Thiem's straight line; a piezometer with zero stabilised drawdown is excluded (it is beyond the radius of influence or was not affected).

Pumping

Readings during pumping: t since the start of pumping, s well and s for each piezometer, in m. Add reading adds a row, and the × removes it.

  • Readings in piezometers give T and S (Theis, Cooper-Jacob, distance-drawdown, Hantush in a leaky aquifer).
  • Readings in the well alone give T; S from the well is not reliable.
  • Distance-drawdown requires at least two piezometers at different distances read at the same time.

Readings with missing, zero or negative times or drawdowns are not used in the straight lines or fitting (the logarithm of zero does not exist).

Recovery

After the pump stops: t′ since the stop and the residual drawdown s′ in the well and piezometers.

The stop time is needed to calculate t/t′ with t = tstop + t′:

  • Pump stopped at the last pumping reading (checkbox, default): the stop is the time of the last pumping reading, shown in parentheses;
  • clear the checkbox and enter Pump stop, from start if the pump stopped after the last reading.

Recovery is only calculated if pumping readings are also present. Zero residual drawdown is excluded from the straight line.

Example

Pumping for 8 hours with the last reading at 7:55:00 and the pump switched off at 8:00:00: clear the checkbox and enter 8:00:00 in Pump stop, from start. Recovery readings start at t′ = 0:00:30, 0:01:00… from the stop, not from the start of the test.

Data to check

A Data to check banner may appear below the title of the two panels. It does not prevent saving: it flags data that is probably incorrect.

Warning Where What to check
Pumping readings are not in time order (row …) pumping a mistyped time; calculations still use the times
Repeated pumping times (rows …) pumping duplicate rows
Drawdown of … m at row …: this is not a physically possible value. steps, pumping over 1,000 m: typing error or units
Drawdown of … m at row …: the water level would fall below the bedrock … steps, pumping well drawdown greater than static water level − bedrock; also check the elevations in Well
The specified pump stop is before the last pumping reading recovery the stop time

Pasting from Excel or CSV

Every table has a Paste from Excel or CSV button: a panel opens below the table (Paste steps, Paste pumping readings, Paste recovery readings). Copy the columns from the spreadsheet or datalogger file and paste them into the text box.

  1. Paste the text, including the header row if you have it.
  2. If necessary, set the options (table below).
  3. Click Preview: the program shows how it has parsed the text and does not write anything.
  4. Check the preview and, in the Goes to column, which series each measurement column belongs to (Well, a piezometer or — ignore —). Changing a choice rebuilds the preview.
  5. Click Replace readings (the table is replaced by the pasted data) or Append to readings (the readings are added to the existing ones and sorted by time). The page reloads with the new data.
Option Choices When needed
Times are auto-detect, elapsed times, clock times if automatic detection is wrong
Unit of numeric times from header, s, min, h times written as numbers without a unit in the header
Unit of discharges from header, l/s, m³/h, l/min, m³/s only for steps, if the header has no unit
Pumping start (Pump stop for recovery) time, or date and time (e.g. 08:30, 12/03/2026 08:30) times expressed as clock times; hidden with elapsed times
Static water level m, same datum as the water-level columns water-level columns (depth to water) instead of drawdowns
Group readings into steps checkbox only for steps: one reading per datalogger row

The preview shows the number of readings (and, for steps, the number of steps), how the times were parsed, the content and unit of each column, the first rows as they will be saved (time in h:mm:ss and in the table unit) and any warnings.

Example

Pumping readings with times in minutes, the well and a piezometer:

t (min) s pozzo (m) s P1 (m)
1   0,42    0,05
2   0,58    0,09

Steps from the datalogger, with date and time:

Data    Ora Q (l/s) s pozzo (m) s P1 (m)
12/03/2026  10:00   2   0,85    0,21

How the text is parsed

  • Separator: tab (copy from Excel), then semicolon, then spaces or comma. With comma as the separator, the decimal separator must be a point.
  • Header: the rows before the first data row. Text rows among the data are ignored, with a warning.
  • Cells: numbers, times (h:mm or h:mm:ss), dates (dd/mm/yyyy, dd-mm-yyyy, dd.mm.yyyy, yyyy-mm-dd and variants) or date and time in the same cell.
  • Columns, from the header: discharge (Q, portata, flow… or a unit such as l/s), time (t, tempo, time, ora, orario, trascorso, durata…), date, level (livello, profondità, soggiacenza, depth, level…; converted to drawdowns), otherwise drawdown. Without a header, the first numeric column is time and the others are drawdowns. If a column is recognised incorrectly, change it in the preview using the Content menu.
  • Units from the header: for times s, min, h (also secondi, minuti, ore); for discharges l/s, m³/h (also mc/h), l/min, m³/s; for drawdowns cm and mm, otherwise m. Without units, times are in minutes and discharges in l/s, with a warning.
  • Clock times versus elapsed times (auto-detect): with a date, they are clock times; then the header decides (trascorso, durata versus ora, orario); plain numbers are elapsed times; h:mm:ss values are clock times if they go backwards (midnight) or if the first reading is more than one hour after midnight with a short interval (08:30, 08:31…).
  • Clock times: elapsed time is the time minus Pumping start. Without a date, a time earlier than the previous one belongs to the next day. Readings before the start are discarded, with a warning.
  • Levels: s = L − L0, where L0 is the specified Static water level; otherwise the last reading with the pump stopped (before the start), otherwise the first reading. The warning states which was used.
  • Series: a column goes to the piezometer whose name or abbreviation appears in the header, or to the well with pozzo, well or PW; the others go, in order, to the well and unassigned piezometers.

Warning

With clock times you must specify Pumping start (or Pump stop for recovery). Without it, the preview assumes the first reading as the start and says so; confirmation, however, is refused: the first reading would become t = 0 with a drawdown already measured, which is not possible.

Tip

Paste the header row with units (t (min), Q (l/s), s P1 (m)). Without a header and without a date column, a discharge column is read as drawdown: in the preview, select discharge from its Content menu.

Group readings into steps. The datalogger records one reading per row. With the checkbox selected, for each constant-discharge interval the last reading before the discharge change is kept, as in the desktop program; intervals with zero discharge are discarded. Without the checkbox, each pasted row becomes a step.

For pumping readings, if the text has a discharge column with a single value and Test discharge is empty, the discharge is also entered there.

Frequently asked questions

I entered 90 as the time and see 1:30:00. With Times in set to h:mm:ss, a number means minutes. Enter 90 s if you meant seconds, or change Times in.

Why is a step not used in the characteristic curve? Its discharge or well drawdown is missing, or one of the two is not positive. The program reports this in the characteristic curve warnings in the Results.

Recovery is not calculated. You need the Test discharge, pumping readings and the stop time: leave Pump stopped at the last pumping reading selected or enter the stop time.

Piezometers do not appear in the tables. Add them on the Well tab, with their distance from the well.