Skip to content

Interpretation methods

This page is the catalogue of methods that GeoTheis NX applies to tests. For each one, you will find the required data, assumptions, results and limitations. You do not choose which ones to calculate: the program calculates all the methods allowed by the data and compares them in the Results tab. A method without the necessary data appears under Not applicable, with the reason.

Formulas are given in abbreviated form. The theoretical background, full assumptions and bibliography are in Theory; how to read graphs, reliability and proposals is covered in Results.

Notation: Q discharge, s drawdown, r distance from the well, t time since pumping started, t′ time since shutdown, T transmissivity (m²/s), K hydraulic conductivity (m/s), S storativity (dimensionless), R radius of influence (m), b thickness of the confined aquifer (top − base), H1 saturated thickness of the unconfined aquifer (static level − base), rw well radius, L screen length.

Which data for which methods

Data entered Methods calculated
Step-drawdown test, 2 valid steps Well characteristic curve (Jacob)
Step-drawdown test, 3 or more valid steps plus Rorabaugh
Step-drawdown test with piezometers plus distance-drawdown on steps, Dupuit-Thiem by step, Cooper-Jacob on test stations
Step-drawdown test with selected critical discharge and assumed radius of influence plus single wells
No valid steps, complete known critical discharge (Qc, sc, assumed R) single wells
Constant-rate test with the well only Cooper-Jacob and recovery on the well: T yes, S no
Constant-rate test with pumping readings in piezometers plus Theis (automatic fitting); with at least two piezometers at different distances, also distance-drawdown
Stabilised drawdowns plus Dupuit-Thiem (steady state)
Leaky aquifer with readings in piezometers plus Hantush (automatic fitting)
Type curve fine-tuning, or a point saved by the desktop program plus Theis or Hantush (match point)

A step is valid if it has positive discharge and drawdown in the well. The data entry rules are in Test; the aquifer type and well penetration are selected in Well.

Note

The aquifer type is decisive: Hantush is calculated only for a leaky aquifer; steady-state Dupuit-Thiem and single wells are not calculated for a leaky aquifer. If the aquifer type is not specified, the constant-rate methods assume a confined aquifer and state this in a warning.

Step-drawdown test

Step-drawdown test methods use end-of-step drawdowns. They describe the well (losses, critical discharge) better than the aquifer: the resulting T and K values are indicative compared with the constant-rate test.

Well characteristic curve (Jacob, n = 2)

Jacob (1947); Walton (1962).

  • Data: at least 2 valid steps at different discharges.
  • Assumptions: drawdown in the well is the sum of a linear aquifer loss and a quadratic well loss.
\[ s = B\,Q + C\,Q^2, \qquad \frac{s}{Q} = B + C\,Q \]

B and C are obtained from the least-squares straight line of s/Q against Q for the valid steps.

  • Returns: B (s/m²), C (s²/m⁵), R² of the straight line, well efficiency E = BQ/(BQ + CQ²), the proposed critical discharge Q = B/C (50% efficiency), well condition according to Walton (C in min²/m⁵) and, when you have selected the critical discharge Qc on the graph: Qopt = 0.9·Qc, sc = B·Qc + C·Qc², the critical specific capacity Qc/sc and the efficiency at the optimum discharge.
  • Does not return T, K, S, R.
  • Limitations: with only 2 steps, the straight line passes through the points and there is no goodness-of-fit check; non-positive B or C indicates steps that are too short or not at steady state. This is the basis of the allowable discharge.
C (min²/m⁵) Well condition (Walton)
≤ 0.5 Properly designed and developed
0.5 – 1 Moderate deterioration due to clogging
1 – 4 Severe deterioration or clogging
> 4 Difficult to restore the well to its original condition

Well characteristic curve (Rorabaugh, variable n)

Rorabaugh (1953).

  • Data: at least 3 valid steps.
  • Assumptions: as for Jacob, with a variable exponent for well losses: s = B·Q + C·Qⁿ (with n = 2, this reduces to Jacob).
  • Returns: B, C, n with the 95% interval, and the root mean square error of the drawdowns.
  • Limitations: with 3 steps, the curve passes exactly through the points; n outside 1.5–3.5 describes the points but does not have Rorabaugh's physical meaning. The result is then indicative.

Distance-drawdown on steps (Thiem)

Thiem (1906).

  • Data: steps with drawdowns in piezometers; for each step, at least two piezometers with drawdown decreasing with distance.
  • Assumptions: for each step, a straight line of s against log10 r (distance-based Thiem), as if conditions at the end of the step were steady.
  • Returns: per step, Δs per logarithmic cycle, T = ln10·Q/(2π·Δs), K = T/b (T/H1 in an unconfined aquifer) and R where the straight line gives s = 0; averages over the calculated steps.
  • Limitations: always indicative (the steps are not at steady state). In a leaky aquifer, T is calculated as for a confined aquifer, without leakage.

Dupuit-Thiem by step

Dupuit (1863); Thiem (1906).

  • Data: steps, fully penetrating well, at least one piezometer, unconfined or confined aquifer.
  • Assumptions: end-of-step drawdowns treated as steady state. With two or more piezometers, the pair consisting of piezometers 1 and 2 is used; with only one, the well–piezometer pair is used.
  • Returns: T and K per step, and averages. In a confined aquifer, T = Q·ln(rb/ra)/(2π·(sa − sb)), K = T/b; in an unconfined aquifer, the Dupuit formula is used, T = K·H1.
  • Limitations: always indicative. With the well–piezometer pair, well drawdown includes head losses and T is underestimated.

Cooper-Jacob on test stations

Cooper & Jacob (1946).

  • Data: steps with the end-of-step Time, fully penetrating well, piezometers, confined aquifer.
  • Assumptions: straight line of s/Q against log10 t for the steps, for each piezometer.
  • Returns: T, S (from the piezometer distance) and K = T/b.
  • Limitations: the steps have different discharges and the straight line does not account for the superposition of effects: the result is indicative and is never used for the design.

Single wells

Dupuit (1863); Thiem (1906); Chiesa; Celico.

  • Data: a critical pair (Qc, sc) and an Assumed radius of influence R; well geometry (rw, screen) and aquifer elevations. The pair comes from the step-drawdown test (Qc selected on the graph, sc = B·Qc + C·Qc²) or, without valid steps, from the known critical discharge entered in Test. Assumed R is entered in that panel in both cases.
  • Assumptions: the critical pair is treated as steady state. Unconfined or confined aquifer; you must specify whether the well is fully or partially penetrating.
  • Returns: T and K for each applicable formula.
  • Limitations: always indicative (assumed steady state, assumed R). It is not calculated for a leaky aquifer.
Well and aquifer Formulas calculated
Fully penetrating, unconfined aquifer Dupuit: K = Q·ln(R/rw)/(π·(H1² − H2²)), T = K·H1, with H2 = H1 − s
Fully penetrating, confined aquifer Thiem: T = Q·ln(R/rw)/(2π·s), K = T/b
Partially penetrating, unconfined aquifer Chiesa (p. 187), with the distance between the bottom of the screen and the base
Partially penetrating, confined aquifer Chiesa formula 5 (type A) or 11 (types B and C), plus Muskat, Kozeny, infinite thickness (Babushkin), Halek, Girinski, Zangar, “L/b − L/2r”

The types of partially penetrating well in a confined aquifer (Chiesa): A screen separated from the top and not reaching the base; B screen adjoining the top and shorter than the thickness; C screen separated from the top and reaching the base.

Warning

Halek, Muskat, Girinski, “L/b − L/2r” and the formula for types B and C are marked to be verified: these are desktop program formulas not yet verified against the reference text. Use them as a check, not as a design value.

Constant-rate test

All constant-rate methods require the Test discharge. Those based on piezometers require the piezometer distance r (Well tab).

Cooper-Jacob (drawdown)

Cooper & Jacob (1946); Kruseman & de Ridder (1994).

  • Data: pumping readings in the well and/or piezometers.
  • Assumptions: logarithmic approximation of Theis, valid for u = r²S/(4Tt) < 0.05: straight line of s against log10 t over the final segment. The program automatically selects the straight-line segment; you can change it (see Cooper-Jacob interval).
\[ T = \frac{\ln 10\; Q}{4\pi\,\Delta s}, \qquad S = \frac{2{,}25\,T\,t_0}{r^2} \]
  • Returns: for each series, T (with 95% interval), K, S and the segment used; averages over the piezometers and R at the end of pumping, R = √(2.25·T·t/S).
  • Limitations: from the well alone, T yes (it includes the effect of losses over the initial segment), S no: S from the well is not reliable and is not included in the average. With fewer than 3 points on the straight line, the series is indicative. In an unconfined aquifer, it applies to drawdowns small compared with H1; in a leaky aquifer, only before leakage becomes apparent.

Recovery (Theis, Cooper-Jacob straight line)

Theis (1935); Kruseman & de Ridder (1994).

  • Data: pumping and recovery readings, and the time of pump shutdown.
  • Assumptions: residual drawdown s′ against log10(t/t′), with t = tshutdown + t′; all valid points are used.
  • Returns: T and K for each series, and average values. It gives neither S nor R.
  • Limitations: with the well alone, the result is indicative. A recovery T differing by more than 30% from the pumping value requires checking the shutdown time and straight-line segment. The point where the straight line reaches s′ = 0 provides information about the aquifer: t/t′ ≈ 1 complete recovery, well above 1 recharge, below 1 an impermeable boundary or finite volume.

Theis (automatic fitting)

Theis (1935).

  • Data: pumping readings in at least one piezometer (well readings are not included).
  • Assumptions: confined, homogeneous, isotropic, infinite aquifer; fully penetrating well; constant discharge.
\[ s = \frac{Q}{4\pi T}\,W(u), \qquad u = \frac{r^2 S}{4 T t} \]
  • Returns: for each piezometer, T and S with the 95% interval, and the standard error between curve and data; averages over the series that converged and R(t) at the end of pumping.
  • How it works: least squares on the logarithms of drawdowns (Levenberg-Marquardt), starting from Cooper-Jacob. The match point is a result, not an input to be selected.
  • Limitations: reliable with a standard error up to 25%, indicative above that, and unreliable if fitting does not converge. There must be more points than parameters. For an unconfined or leaky aquifer and a partially penetrating well, it is calculated with a warning.

Hantush (automatic fitting)

Hantush & Jacob (1955); Hantush (1956).

  • Data: leaky aquifer (unconfined or confined), pumping readings in at least one piezometer.
  • Assumptions: as for Theis, plus leakage from a semipermeable layer without storage; third parameter r/B.
  • Returns: T, S, r/B for each piezometer; the leakage factor B = r/(r/B) and the hydraulic resistance c = B²/T of the semipermeable layer; averages and R(t).
  • Limitations: if r/B falls below 0.001, leakage is not visible in the data: the program repeats the fitting with Theis and B and c cannot be determined. Storage in the semipermeable layer is not considered.

Theis and Hantush (match point)

  • Data: one match point per piezometer, created by Fine-tuning the type curve (see Type curve fine-tuning) or from a desktop program file.
  • Returns: T = Q·W/(4π·s), S = 4·T·u·(t/r²); for Hantush, also B and c.
  • Limitations: indicative at best; unreliable if the point curve is far from the data (standard error above 50%) or gives S > 1. It is never proposed on its own: you put it into use with Use for the design.

Dupuit-Thiem (steady state)

Dupuit (1863); Thiem (1906).

  • Data: Stabilised drawdowns in piezometers (Test tab), fully penetrating well, unconfined or confined aquifer; H1 for an unconfined aquifer.
  • Assumptions: steady state. With two or more piezometers, a straight line of s against log10 r using only the piezometers; R where the straight line gives s = 0. In an unconfined aquifer, the straight line is based on Z = s·(2H1 − s).
  • Returns: T, K, R; with two or more piezometers and the stabilised drawdown in the well, also the theoretical drawdown at the well wall and the well head losses (measured − theoretical).
  • Limitations: with only one piezometer, the well–piezometer pair is used and the result is indicative. It does not apply to a leaky aquifer (use Hantush) or to a partially penetrating well.

Distance-drawdown (Cooper-Jacob)

Cooper & Jacob (1946); Kruseman & de Ridder (1994).

  • Data: at least two piezometers at different distances, read at the same pumping time.
  • Assumptions: straight line of s against log10 r at time t; the program uses the last pumping reading in which at least two piezometers have a drawdown. The well is not included.
  • Returns: T = ln10·Q/(2π·Δs), r0 where s = 0 (used as R), S = 2.25·T·t/r0².
  • Limitations: reliable with 3 or more piezometers; with 2, the straight line passes through the points. At that time, u must be below 0.05 even at the farthest piezometer.

Derived quantities

  • K: taken from the method; if the method gives only T, K = T/b for confined and leaky aquifers, and K = T/H1 for an unconfined aquifer. Without the thickness, K is not calculated.
  • Transient R: R(t) = √(2.25·T·t/S) at the end of pumping, from methods that give T and S.
  • Design value, allowable discharge and cone of depression are not methods: the program derives them from the calculated methods. See Design value, Allowable discharge and Cone of depression.
Method T K S R Other Reliability at best
Well characteristic curve (Jacob) — — — — B, C, E, Qc, Qopt, sc, Walton reliable
Rorabaugh — — — — B, C, n reliable
Distance-drawdown on steps ✓ ✓ — ✓ per step indicative
Dupuit-Thiem by step ✓ ✓ — — per step indicative
Cooper-Jacob on stations ✓ ✓ ✓ — never for the design indicative
Single wells ✓ ✓ — — per formula indicative
Cooper-Jacob ✓ ✓ ✓ (piezometers) ✓ segment used reliable
Recovery ✓ ✓ — — t/t′ at s′ = 0 reliable
Theis (fitting) ✓ ✓ ✓ ✓ 95% intervals reliable
Hantush (fitting) ✓ ✓ ✓ ✓ r/B, B, c reliable
Match point ✓ ✓ ✓ ✓ B, c (Hantush) indicative
Steady-state Dupuit-Thiem ✓ ✓ — ✓ well losses reliable
Distance-drawdown ✓ ✓ ✓ ✓ (r0) time used reliable

The complete reliability criteria and the order in which the program selects the method to propose are in Results.


Found an error on this page? Let us know or open a Pull Request.