Step 3 describes the wall section by elements. All dimensions are in metres, slopes in degrees. Every field is saved when you leave it: the section in the centre is redrawn and the checks are updated. The dimensions of the section can also be changed with a click on their value in the drawing.

Reference¶
The calculation is per metre of wall. The toe side (downhill) is on the left, the backfill (uphill) on the right. The wall coordinates have x = 0 at the toe edge of the foundation and y = 0 on the founding plane; the moment pole for overturning is the toe corner of the base. At the top of the stem panel the app shows the base width that results from the dimensions.
Stem¶
| Field | Unit | Notes |
|---|---|---|
| Stem height | m | from the foundation to the top |
| Top thickness | m | |
| Front batter | m | projection of the front face foot relative to the top |
| Back batter | m | used only with a battered back face (chosen in Wall type) |
| Top shift | m |
With a stepped back face the list of steps appears (Rise and Tread, from the top): the sum of the rises is the wall height and the last tread is 0.
Foundation¶
| Group | Fields | Notes |
|---|---|---|
| Toe | Length, Edge depth, Haunch | the haunch is the increase in depth from the edge to the stem |
| Heel | Length, Edge depth, Haunch | the soil above the heel enters the checks as stabilising weight |
| Slopes and length | Base inclination (°), Heel face inclination (°), Wall length (m) | the founding plane can be inclined only with a shallow foundation or with shear key; the wall length is used only for quantities |
Shear key¶
The panel opens when the foundation in the Wall type step is With shear key. Fields: Width, Depth and Distance from the heel edge (m). The shear key increases the sliding resistance: the sliding plane passes through its bottom.
Shelves and blinding¶
Each part has a switch, the same as in the Wall type step.
| Part | Fields |
|---|---|
| Back shelf | Width, Depth, Distance from the top (m) |
| Front shelf | Distance from the top, Overhang, Depth at root, Depth at tip (m); Number of bars; Bar diameter (mm) |
| Blinding concrete | Projection, Thickness (m) |
The actions carried by the front shelf are entered as point loads in the Loads step: without them the shelf is designed with the minimum reinforcement.
Checks on the data¶
A negative dimension, a foundation narrower than the top thickness, a shear key outside the foundation or a founding plane inclined more than 45° are errors: they appear next to the field and in the "To check in the project" box, and the wall is not calculated until you fix them. Warnings (for instance a code that the first release does not compute) do not stop the calculation.