RC sections, piles and anchors¶
Reinforced-concrete sections¶
Sections are rectangular, one metre wide, with two layers of reinforcement at the cover distance from the faces. They are checked by the GeoStru RC section solver, the same as in MP NX.
ULS bending with axial force¶
Concrete with the parabola-rectangle law (\(\varepsilon_{c2}=0.2\,\%\), \(\varepsilon_{cu}=0.35\,\%\), \(f_{cd}=\alpha_{cc}f_{ck}/\gamma_c\)), bilinear steel. The M-N domain is built over thin strips of the section; the check compares the point (NEd, MEd) with the domain and returns the demand/capacity ratio.
With NTC 2018 the resisting moment is the first-yield moment: the smaller of the one that brings the steel to yield and the one that brings the concrete to a compressive strain of 0.2 %. It is lower than the ultimate moment (about 10 % with small axial force) and corresponds to the essentially elastic check that the code requires of foundations in the seismic combination; the desktop program applies it to all sections and all combinations, and MDC NX does the same.
Shear¶
Members without shear reinforcement, NTC 2018 eq. (4.1.23):
with \(k=1+\sqrt{200/d}\le 2\) (d in mm), \(\rho_l=A_{sl}/(b_w d)\le 0.02\), \(\sigma_{cp}=N_{Ed}/A_c\le 0.2f_{cd}\), \(v_{min}=0.035\,k^{3/2}f_{ck}^{1/2}\).
Serviceability¶
Stresses on the cracked section (n = 15) and crack width (2019 Circular, C4.1.2.2.4):
with kt = 0.6 for short-term loading and 0.4 for long-term loading, k2 = 0.5 for bending, ρeff referred to the effective area of concrete in tension.
Piles¶
Actions at the head¶
The horizontal force H, vertical force V and moment M of phase II, for the share of load given to the piles, are transferred to the centroid of the pile heads. With the resultant moment the equilibrium of all actions is used; with the overturning moment (prudent choice) only the overturning contributions.
Distribution: rigid cap¶
The cap is a rigid body with three displacements (u, w, θ). Each pile reacts with an axial stiffness ka and a transverse one kt; the equilibrium \(\mathbf{K}\,\mathbf{d}=(H,V,M)\) gives the displacements and hence N, T (and M with a fixed head) of every row. With vertical piles and negligible transverse stiffness the classic distribution is recovered:
- Axial stiffness (Randolph and Wroth): elastic settlement of the pile in the soil with the mean modulus of the layers along the shaft, plus the shortening of the pile.
- Transverse stiffness (Hetényi, long pile): with the characteristic length \(L_b=\sqrt[4]{4E_pI_p/(k\,D)}\), free head \(k_t=2E_pI_p/L_b^3\).
- Fixed head: Hetényi's matrix adds the fixing moment, which enters the check of the pile.
Vertical bearing capacity¶
Nq of Berezantzev as a function of φ′ at the toe and of the ratio L/D, \(N_c=\max\{(N_q-1)\cot\varphi';9\}\). The coefficients K·tanδ and the adhesion α depend on the pile type (bored or driven) and on the cohesion. For raked piles the true depth of the toe and the shaft length in each layer are used. The design resistance is
with ξ = max(ξ3, ξ4) from the number of investigated verticals (NTC 2018 Table 6.4.IV) and γb, γs from Table 6.4.II. A pile in tension counts only the shaft resistance, reduced to 70 %. The group efficiency (Converse-Labarre), if chosen, multiplies the resistance:
with i the spacings in the row and between rows, m the number of rows, Eg between 0.3 and 1.
Lateral loading¶
Long pile on an elastic subgrade. With a constant subgrade modulus (Hetényi), head displacement, rotation and moments along the shaft come from the closed-form solutions with Lb; with a modulus increasing with depth (Matlock and Reese) from the relative stiffness length \(T=\sqrt[5]{E_pI_p/n_h}\) and the non-dimensional coefficients Ay, By, Am, Bm. The soil pressure is compared with the limit lateral pressure.
Seismic action¶
The inertial actions of the wall reach the piles already in H, V and M of the seismic combination, without reducing their resistance. With subsoil D or E, NTC 2018 also asks to consider the moments from kinematic interaction: the app reminds you of it.
Anchors¶
The anchor acts on the stem with the design force per metre of wall \(T/i\) (i spacing), inclined by the anchor angle α. The resistance of the anchorage is the smallest of three:
| Resistance | Depends on |
|---|---|
| Grout body in the soil | diameter and length of the bond, effective stress at the depth of its centroid, φ′ and c′ of the layer, divided by γR·ξa (NTC 2018 Tables 6.6.I and 6.6.III) |
| Grout-strand bond | \(\pi\,n\,d_{tr}\,L_a\,\tau_{ad}\) |
| Steel | area of the strands times the design strength, net of prestress losses |
References¶
- Hetényi M. (1946), Beams on Elastic Foundation, University of Michigan Press.
- Matlock H., Reese L.C. (1960), Generalized solutions for laterally loaded piles, J. Soil Mech. Found. Div., ASCE, 86(SM5).
- Randolph M.F., Wroth C.P. (1978), Analysis of deformation of vertically loaded piles, J. Geotech. Eng. Div., ASCE, 104(GT12).
- Poulos H.G., Davis E.H. (1980), Pile Foundation Analysis and Design, Wiley.
- Berezantzev V.G., Khristoforov V.S., Golubkov V.N. (1961), Load bearing capacity and deformation of piled foundations, Proc. 5th ICSMFE, Paris.
- Converse F.J., Labarre W.M., group efficiency formula, in Bowles J.E., Foundation Analysis and Design.
- D.M. 17/01/2018 §4.1, §6.4.3, §6.6; Circular 21/01/2019 no. 7, C4.1.2.2.4.