Soils and water table¶
Step 4 has three panels: Stratigraphy, Ground profile and Backfills. Levels are in the wall system (y = 0 on the founding plane, positive upwards), in metres.
Stratigraphy¶
Layers are read from top to bottom and are contiguous: the top of a layer is the bottom of the one above and is changed from there (the top field is read-only from the second layer down). + Layer adds a 3 m layer below the last one, with the same parameters; the bin removes it. Up to ten layers. For each layer, besides the description:
| Field | Unit | Notes |
|---|---|---|
| Top level | m | |
| Bottom level | m | |
| Unit weight γ | kN/m³ | below the water table the program uses γ − γw |
| Friction angle φ | ° | |
| Cohesion c (cu with φ = 0) | kPa | with φ = 0 the layer is undrained |
| Wall friction δ | ° | usually 2/3 of φ; δ = 0 is a smooth wall |
| Young's modulus | kPa | used by the piles |
| Top inclination | ° |
A layer needs a friction angle or a cohesion greater than zero.
Water table¶
The water table is given as Water table level (from the founding level), in metres, with Set the water table; Remove the water table deletes it. The layers below the level are submerged (drop icon) and the layer cut by the level is split in two. In the section the water table is a dashed blue line with its level.

Below the water table the soil pushes with its submerged weight, the water adds its hydrostatic pressure on the stem and the base of the wall receives the uplift (downhill the water table is taken at most at ground level).
Note
The desktop program applied no uplift on the base. MDC NX does: with a high water table sliding, overturning and bearing capacity can be less favourable than in the desktop. See Validation and limits.
Ground profile¶
A table with three segments uphill, measured from the top of the wall, and one segment downhill, from the foundation edge: for each, Length (m) and Slope (°). Below the table:
| Field | Unit | Notes |
|---|---|---|
| Fill above the top | m | negative: lowered ground level |
| Fill unit weight | kN/m³ | |
| Embedment below the front ground | m | the downhill soil above the founding plane |
For the earth pressure the program uses, like the desktop, a design slope of the backfill: the line from the top of the wall to the point where the failure wedge, starting from the heel corner of the foundation, meets the profile. If the wedge does not meet the profile, the slope of the first uphill segment applies. The downhill slope enters the bearing capacity (ground slope factors).
Backfills¶
Two switches: Backfill behind the wall and Fill on the toe. Each has Thickness (m), Unit weight γ (kN/m³), Friction angle φ (°), Cohesion c (kPa), Wall friction δ (°) and Drain height (m).