General data and wall type¶
The first two steps collect what applies to the whole project: who, where and what kind of wall. The code and the analysis options are in the Code and seismic action step.
General data and site¶
Step 1 has three panels. The data are typed in the form and stored with Save.
| Panel | Fields |
|---|---|
| General data | Description, Client, Site, Designer, Date |
| Site location | Address or place (with Search), Latitude, Longitude, Elevation [m], map |
| Engineering firm | Header, Street, Town, Province, Postcode, Phone, E-mail, VAT number |
Description, site, designer and engineering firm go into the report. For the site click on the map or drag the marker: latitude and longitude (WGS84) are updated. Search finds the place typed in the address field. The coordinates are used by the Code and seismic action step to obtain the seismic hazard parameters of the site.
Wall type¶
Guided setup¶
In a project without a wall, step 2 shows the guided setup (the same as the desktop): choose the type, type the Stem height (0.5 to 20 m) and press Create the wall. The seven choices:
| Choice | Wall created |
|---|---|
| Cantilever | RC cantilever, longer heel |
| Cantilever, toe foundation | RC cantilever, longer toe (when there is no room uphill) |
| Gravity | plain concrete |
| Basement | RC cantilever restrained at the top (floor slab) |
| On one, two or three rows of piles | RC cantilever on bored piles |
The proposed dimensions follow the rules of the desktop program:
- cantilever and piles: base 0.7·H, top thickness and front batter 0.30 m, foundation depth H/10 (0.40 m if the result is less than 0.35 m), toe one third of the base (or heel, with the toe foundation);
- gravity: top thickness 0.40 m, front batter 0.2·H, toe H/3;
- piles: diameter 0.40 m, length 12 m, first row axis 0.60 m from the toe edge, spacing 1 m.
The setup also adds a sand layer (γ = 17.65 kN/m³, φ = 36°, δ = 24°) and the materials C25/30 and B450C. It is a starting point: the checks tell you whether it works. With a wall already defined, the setup is available again at the bottom of the step under Start over with the guided setup: it replaces the wall (general data and site stay) after a confirmation strip.

Structure, foundation and optional parts¶
With the wall defined, the step shows three panels.
| Panel | Choices |
|---|---|
| Structure | RC cantilever, Gravity, On piles |
| Foundation | Shallow, With shear key, One row of piles, Two rows of piles, Three rows of piles, Free pile rows |
| Profile and optional parts | Back face (Vertical, Battered, Reverse battered, Stepped); Basement wall (restrained at the top); Back shelf; Front shelf; Blinding concrete |
With a piled foundation the wall becomes "on piles"; with the shear key the app proposes its dimensions, to be adjusted in Geometry. The piled foundation applies only to the cantilever wall: with a gravity wall the app reports an error and does not compute. The dimensions of the optional parts are typed in the Geometry step.
Note
Gabion or block walls, stone masonry walls and counterforts in a desktop project open and stay in the file, but their calculation comes with the second release: the app says so in the step.
Found an error on this page? Let us know or open a Pull Request.